Fixed CIP Station Skid
Technsys offers Fixed CIP (Cleaning in Place) Station Skids that provide a permanent, high-efficiency solution for maintaining hygiene and sanitation in various industrial processes. Designed to integrate seamlessly into your production line, these CIP station skids ensure thorough and consistent cleaning of equipment, minimizing downtime and enhancing operational efficiency. With robust construction and advanced cleaning technology, the fixed CIP stations deliver reliable performance and are customizable to meet specific industry requirements, ensuring optimal cleanliness and compliance with hygiene standards.
Product Details:
Control Panel System | 10″ Touch Screen Allen Bradley HMI & PLC Control System |
Number Of Tanks | 2 |
Tank Size | 1000 L(Both Tank Size) |
Voltage | 440 V AC |
Surface Finishing | Glass |
Power Source | Electric |
Phase | 3 Phase |
Material | Stainless Steel |
Material Grade | SS 304, 316 |
Frequency | 50-60 Hz |
Brand | Technsys |
Clean-in-Place (CIP) is a method of cleaning the interior surfaces of pipes, vessels, process equipment, without disassembly. The benefit to industries that use CIP is that the cleaning is faster, less labor-intensive and more repeatable, and poses less of a chemical exposure risk to people. Manual CIP skids have a balance tank, centrifugal pump, and connection to the system being cleaned. Fixed CIP stations include fully automated systems with PLC, multiple balance tanks, sensors, valves, heat exchangers, data acquisition and Spray balls. The Steam-In-Place (SIP) System is responsible for repeatedly steaming areas of product contact to reduce the bio-burden on the system. The steam system must be able to measure and control steam temperature, pressure, and/or flow to ensure adequate steaming.
Each equipment is designed (in single or multi-tank configuration) to achieve the most effective and easily available cleaning systems, starting from:
- Type, size & location of equipment to be washed
- Required type of water and chemical agent
- Soiling levels of the product to be removed
- CIP Supply & Return pump requirements
- Cleaning Spray Balls/nozzles type
- Washing sequence, automation level
- Heating arrangements
In CIP/SIP automatic stations, CIP critical parameters integrated are:
- Contact time of solution
- CIP Supply & Return temperature
- Chemical conductivity for wash solutions
- CIP solution flow rate & pressure
- Tanks levels
Above parameters can be constantly monitored by the PLC and managed with cost-savings criteria. CIP/SIP System can be customized with different washing cycle programs.
Applications:
- Fermenters, Vessels, Storage Tanks
- Bioreactors, Mixers, Silos
- Buffer preparation hold systems
- Formulation systems
- Closed loop Equipment & piping systems, viz Process Piping, Heat exchangers, Boilers, Pasteurizers, etc
Specifications
- It consists of the following elements:
- One SS 304 tank, jacketed 1500L for recovered water with a conical bottom. Fitted with static spray ball.
- Heating carried out by a Tubular steam heat exchanger, with a Pneumatic steam control valve, drains & Steam condensate valve.
- Air operated double diagram pumps (MOC-PP/PTFE) for concentrate chemical dosing.
- 5.5 kW, SS 316L with Mech. Seal-C/SiC & EPDM seals, CIP Supply pump with VFD & 5.5 kW self-priming pump for CIP return. Both pumps fitted with SS 304 Shrouds.
- Pneumatic butterfly valves, SS 316L with actuators w/o feedback
- SS 304 Skid with adjustable level pads.
- Level control in the tanks.
- A flow switch, Temperature & Conductivity controller, Inline Strainer (0.5 mm screen) & Sampling valve mounted in the CIP return line.
- Flow & Pressure transmitter, Temperature controller, Heat exchanger, Pressure gauge mounted on the CIP supply line.
- SS 304 Control cabinet with 10″ touch screen Allen Bradley HMI & PLC control system.
- 5 program preparation: Short tank cleaning, short line cleaning, tank long cleaning and long line cleaning, Manual valve activation. Plant state displaying, Change of parameters.